Pilot problem with Weil-Mclain boiler
Hi guys, I hope some one on this board can give me a little guidance. I have an intermittant problem where my standing pilot goes out every now and again. I cleaned the pilot (was already clean) and I replaced the thermocouple already. I also checked the pilot size with the boiler running and it doesn't seem to change from when the boiler is not running. After comparing to my brothers boiler (same model) I came to the conclusion that the pilot may be a little low and possibly blowing out. The gas valve is a Honeywell VR8300C4050 according to Weil-Mclain specs. I attempted to turn up the pilot as shown in the instructions and the screw does not seem to have any affect on the pilot, even if I turned it 2 or 3 times. From past experience on stoves etc. a quarter of a turn is usually enough to make a difference. At this point I'm guessing that I need a new gas valve. Is there any other possibilities that I overlooked? If I replace the gas valve, does it have to be adjusted to my boiler, or is it factory preset to work fine? Thanks in advance for any help. Chris I have an update..... I forgot to mention that when I first got the boiler (in new house) I replaced the thermocouple after about 1 1/2 years for an intermittant problem where the pilot would fail. After replacing it, I had a failure the other day for the first time, the thermocouple is about 1 1/2 years old again. Well I tried adjusting the flame again, and apparently the pilot screw was so wide open from the factory that it sounded like a blow torch. It took about 3 turns closed for it to do anything. Once I closed it the flame seemed the same height but quiet. I now have a theory on the failures that I have been having. Either the pilot was so strong that it was not a stable flame and would blow out easier, or (the theory that I think is correct) the flame was so strong that it over heated and kept ruining the thermocouples every year or so. Based on my findings I think that the gas valve is fine. What do you guys think? Anything is possible I guess... one other consideration to keep in mind: Downdrafts in the chimney. Can you correlate the pilot being out with windy conditions? NJ Trooper, Thanks for the reply. I don't think it's associated with wind. I have been through some extremely heavy winds with no problems, it was pretty nice weather when this last episode occurred. I forgot to mention that I am in a new development, the houses around me have the same boiler and the same chimney system. I asked around and none of my neighbors had a problem in the past 3 years since we all moved in. I'm keeping my fingers crossed that I fixed it. So far it's good.....but it's only been 1 day LOL. Thanks again, Chris Chris, I'm guessing that you've got the paperwork for your valve, but if not, this might be helpful... VR8300 Gas Control I wonder if the installers ever bothered to check/adjust the regulator... I wouldn't recommend that you try this yourself, without the proper gauges it's difficult (and maybe dangerous)... but just a thought... especially with the pilot flame adjustment being all the way out. Thanks!! It should be fine now.....keeping my fingers crossed!!
Related Posts:
Problem with peerless gas boiler
Problem with PEERLESS Gas BoilerI have a cast iron gas boiler circa 1991 that has been running perfectly until yesterday. I routinely (weekly to bi-weekly) check the sight glass, purge rusty water...
Please help weil mclain boiler problem
Please Help - Weil McLain Boiler ProblemHello everyone, I'm hoping that someone out there can help me with this problem. I've got an Ultra Series 2 Gas fired boiler that continues to plague me wit...
Pilot light problem on a carrier gas furnace
Pilot Light problem on a Carrier Gas furnace[SIZE=3]I have a carrier Gas Furnace that has a problem with the pilot light. I will try to describe the problem. It has an automatic pilot igniter. Som...
Lennox whisper heat problem
Lennox whisper heat problemI have a Lennox whisper heat that is 12 years old. What it does is shut off during a call for heat and not come on until someone manually turns it off and back on via po...
Problems with grundfos ups 1542f pump and my boiler heating system
problems with Grundfos UPS 15-42F pump and my boiler heating systemHi Guys, First post here. We bought a house this summer and it has a in-floor heating system with a boiler. The boiler is working...